Usage:
YFN 100A, 200Aseries contactors are suitable for electric control system of electromobile, motor forklift truck, especially for the maintenance of vehicles.
Brief Technical Data:
| Number | Type and parameter | Coil& rated volt of contact circuit(v) | |||||||
| 12 | 24 | 30 | 36 | 40 | 48 | 72 | 80 | ||
| 1 | YFN100A coil hold current(A) | |
0.83 | |
|
|
1.65 | |
|
| 2 | YFN200A coil hold current(A) | |
0.73 | |
|
|
1.45 | |
|
| 3 | YFN100A main rated load current of contact circuit(A) | Resistive loadて=1ms,100A,Inductive load(DC-5)60%lefor resistive load Max.Rated working current of contact circuit for400A,10msMax, | |||||||
| 4 | YFN200A main rated load current of contact circuit(A) | Resistive loadて=1ms,200A, Inductive load(DC-5)60%le for resistive load Max.Rated working current of contact circuit for 800A,10ms | |||||||
| 5 | voltage | 50Hz 1000V AC 1min | |||||||
| 6 | Operating time | pickup(contact makes)≯30ms:release(contact breaks)≯30ms | |||||||
| 7 | Action characteristic | pickup(contact makes)≯66%Us release(contact breaks)≯30%Us,≮5%Us | |||||||
| 8 | Mechanical life | 1 million times | |||||||
| 9 | Electric life | Resistive load:50000times Inductive load 60%le for resistive load 20000times | |||||||
Specifications subject to change as the custom request
Environmental condition:
1. Ambient temperature:-25~+40℃
2. Altitude range:0~2000m
3. Max.relative humidity90% at 25℃
4. Vibration:10~50Hz,10m/s2
5. Shock:30m/s2
6. Installation method:anywhere
7. Voltage fluctuating:0.7~1.1Ue
8. Duty:8h continuous
Configurational mounting diagram:
Circuit diagram:
Nomination(nomogram):