Application:
YFT200L , YFT200A series DC contactors are suitable for the battery or the rectification power, using for handling drawing, the pump motor and other electronic vehicles.
Brief Technical Data:
| Number | Type and parameter | Coil and rated volt of contact circuit(v) | ||||||||
| 12 | 24 | 3 0 | 36 | 40 | 48 | 60 | 72 | 8 80 | ||
| 1 | Coil power dissipation <15(w), Max.coil current(A) | 0.98 | 0.58 | 0.45 | 0.35 | 0.32 | 0.28 | 0.25 | 0.2 | 0.18 |
| 2 | main rated load current of contact circuit(A) | Resistive load:て=1ms 100A Max.Rated working current of contact circuit for 4le, 5 seconds. | ||||||||
| 3 | voltage | 50Hz 1000V AC 1min | ||||||||
| 4 | Operating time | Pickup(contact makes):≯30ms , Release(contact breaks):≯30ms | ||||||||
| 5 | Action characteristic | Pickup(contact makes):≯66%Us Release(contact breaks):≯30%Us,≮5%Us | ||||||||
| 6 | Mechanical life | 1 million times | ||||||||
| 7 | Electric life | Resistive load:20000times, inductive load(DC-5):60%le for Resistive load,10000times | ||||||||
| Notice: 1. Specifications subject to change as the custom request 2. Coil voltage in above 48V with permanent magnet blowouts. |
||||||||||
Environmental condition:
1. Ambient temperature:-25~+40℃
2. Altitude range:0~2000m
3. Max.relative humidity90% at 25℃
4. Vibration:10~50Hz,10m/s2
5. Shock:30m/s2
6. Installation method:anywhere
7. Voltage fluctuating:0.7~1.1Ue
8. Duty:8h continuous
Configurational mounting diagram:
Circuit diagram:
Nomination(nomogram)